MEDITECH IV Stop Time Best Practice Set Up Guide

From Galen Healthcare Solutions - Allscripts TouchWorks EHR Wiki
Jump to navigation Jump to search

EDM Toolbox Parameters

In the EDM Toolbox parameters, your facility can define how many hours to keep DC’d meds active for. This is important in having those IV’s appear on the IV flowsheet to be documented. Also use this dictionary to select your IV Flowsheet Key (make sure this matches the same parameter in the PCS toolbox) The IV flowsheet key can either be set to Route of Administration or Order Type (as shown below.) This parameter setting will drive what types of medications/IV’s appear when using the IV special instance type. These Routes or Order Types are defined in the Med Documentation Workload Dictionary.

MEDITECH IV Charge Capture Setup Guide EDM Toolbox Parameter.png
EDM Toolbox MAR 1

Medication Documentation/Workload Dictionary

Once your IV Flowsheet Key parameter has been defined for both EDM and PCS, you can specify which routes or order types are IV’s in the Med Documentation Workload Dictionary. In the example below we have chosen Order Type as our key, and listed out the individual order types (by Location) that we want to appear on the IV flowsheet.

Pro Tip: Make sure to chat with the Pharmacy Department at your hospital as occasionally, some IV’s are set up as a MED order type. In this instance its best to set your key to Route of Administration as it might be more accurate in pushing the IV’s to the flowsheet.

MEDITECH Med Doc Workload Dictionary IV Flowsheet.png
Med Doc Workload Dictionary: IV Flowsheet

Instance Type Dictionary

Next build a special instance to pull your IV’s onto the flowsheet in the Instance Type Dictionary. For this build, make sure to choose IV Auto as we want all IV’s to appear on our sheet. Rules will later drive the user to document the DC date and time making sure we can accurately report on them.
MEDITECH Instance Type Dictionary BUILD IV AUTO.png
Instance Type Dictionary, BUILD: IV.AUTO

Documentation Section Dictionary

In the Documentation Section Dictionary, you can build your assessment. Use or build any queries to assess the IV intake of your patient. Be sure to set your Recall mode to Automatic so your running IV’s will populate when opened.

MEDITECH Documentation Section Dictionary Main.png
Documentation Section Dictionary: Main

On the Question Sets tab, add your IV Auto instance type by making the label repeatable. This will open the same question set for each ordered IV.

Pro Tip: A completed section can also be added to make sure that all documentation is complete, even if there are no IV’s to document you can still chart against the required intervention allowing you to proceed with discharge.

MEDITECH Documentation Section Dictionary Question Sets.png
Documentation Section Dictionary: Question Sets